Need to download quality pack bundle for hpux inte. The specified username must represent a valid hpux user on the local host. These bundles contain patches that hp has assembled to meet a specific need. Hpux patches are sd products, but igniteux can only manage sd bundles. Hp releases patch bundles for hpux every 6 months i. Hpux 11i package and patch information for the ibm informix database server the product is built on hpux 11.

Hardware enablement bundle if you are adding new hardware, then install this bundle. You have a bundle, but you do not want the default name bundle. The hpux 11i v1 qpk is available on support plus media to all customers under a then current support agreement. Find answers to check latest patches installed on hpux from the expert community at experts exchange. Patch installation commands in hp ux sysadminshare. Hpux software assistant has all the capabilities of the hpsc patch assessment tool and more. The following command sets the bundle name b and the tilte of the bundle t. Check the configuration definitions in the perties file, as described in configuring the offline hpux patch downloader. This bundle is an hp bundle and contains enhancements to various commands to understand the new disk layout version 6 and later. Patch bundles play an important role in patch management. Prechecks for oracle 11gr2 rac installation on hpux. Ok, is there a way to find out when the last generalrelease patch bundle is from.

This article explains a method to create a software distributor depot with all hp ux fibre channel driver bundles for an specific hp ux release. This command is available on the data protector cell manager. My bundle which is in depot tmp patch depot has two patches eg x and y when i add hp ux bundle and select tmp patch depot it. Your first encounter with patch bundles might be with the standard hpux patch bundles. Need to download patch bundle for hpux 11i v3 i would just configure swa with your proxy and your system will analyze itself and download any bundles and patches it needs. Login into the igniteux server if the target system to be installed does not currently have a directory in varoptigniteclients but is up and running, then use the ignite gui to create that directory using the add new client for recovery. Move the patch download file to a file system with enough free space. First, you need to the depots using swcopy to a central location. A patch bundle is a collection of patches that have been grouped into a single software object to meet a specific need. For example, to update to hp ux 11i v3 and install the hp ux 11i v3 base oe, insert the hp ux 11i v3 dvd in the local drive mounted at dvdrom.

My bundle which is in depot tmppatchdepot has two patches eg x and y when i add hpux bundle and select tmppatchdepot it. Hpux 11i version 3 operating environment update release. Install the latest quality pack patch bundles delivered on the support plus release. Create a network depot only if you intend to update other systems on the network using a depot. How do i get the recommended golden patch or bundle patch. Hpux 11i v3 2017 operating environment update release oeur. This post is a howto guide that has steps to install, configure and verify patch or software on hpux operating system.

Many hpux users find that acquiring and installing these bundles, as opposed to acquiring and installingpatches individually, simplifies the patch. Importing hpux depots the hpux depot importer script makes it easy to import hpux patches, bundles, and depots to the. Then it wants you to verify the download with the swverify command, like so. Edit this script and change the line that makes the file interactive when it is run. Check latest patches installed on hpux solutions experts. Operating systems hpux installation of many patches bundle. It is possible to use a nonprivileged account for wbem communication.

The hpux oe media provides standard hpux patch bundles for hpux core. Patch management has sections that display your patch privileges, patches available for any system, patches for your uploaded hpux system, and links for. Aug 25, 2009 to be able to do so we have to patch the boxes before we can use it. Note reference information for swinstall can be found. This allows you to update all systems on the network without having to move media from system to system. Swa combines the versatility and power of the hp it resource center itrc patch assessment and security patch check spc utilities, and is the hp recommended utility to use to maintain currency with hp published security bulletins for hp ux software. Select the most recent release name for your operating system by release date. Q quality pack qpk a bundle of hpux defectfix patches for proactive patching. Also, if individual patches are planned to install then patch id needs to be known to download from hp portal. Where can i download hpux bundle rather than download one by one. I know that hp do distribute generalrelease patch bundles i think quarterly if im not mistaken. Hpux 11 patch bundle install problem solutions experts.

The hpux 11i september 2005 quality pack patch bundle provided support for etc dld. Click on the date and it will expand to show items like qpk, feature and hwe hardware enablement. Standard patch bundles are collections of patches that have been thoroughly tested together. Dec 27, 2016 this post is a howto guide that has steps to install, configure and verify patch or software on hpux operating system. The hpux link will take you to the patch bundles by release date. Select the create as container database option to create the database as a multitenant container database cdb that can support one or more pluggable databases pdbs. Installation of vrtsodm package and patch bundle may display following errors. Home uncategories depots hpux depots hpux add comment edit. If you have not patched your system since 2008, the majority of those patches will have dependencies on other patches. Jul 10, 2016 hpux software assistant standard hpux patch bundles. So you downloaded your qpk after doing swainv analysis of what patches your hpux server fleet needs. To list out products in a bundle steps for creating a hp depot. Swinstall is the exclusive software package installation tool for agilent 3070 family controllers operating with hp ux. No hpux patches are available without an hpe software support contract.

Go to the actions menu and select match what target has on hpux 10. Copy all patch bundles and hp ux patches from the defined workspace to removable storage. Hpux software assistant swa is a tool that consolidates and simplifies patch management and security bulletin management on hpux systems. Step 3 install since you have created a depot, the system may reboot only once, depend what you install. Find answers to check latest patches installed on hp ux from the. Swinstall is the exclusive software package installation tool for agilent 3070 family controllers operating with hpux. Hpux 11i version 3 2017 update standard name and dvd labels hpux 11. Step by step nfs server and client configuration in hpux nfs allows a client computer to access a file system that resides on another computers disks, as though the file system were installed locally. To be sure that your hpux system is reliable and secure. A patch bundle is a set of patches for hp ux that have received extra testing as a group and are packaged together, with the individual patches intact. Electronic software notifications and delivery the hpux 11i v3 electronic software delivery model has been extended worldwide.

Use this procedure to download all patches using the hpux patch downloader. Actions patch bundles the following bundles are recommended by hp. The hpux 11i v1 qpk is also available on the hpux section of the hp enterprise business community website. Hpux 11i v1 december 2009 hp updated the quality pack qpk patch bundles for hpux 11i v1. Hp ux software assistant swa is a tool that consolidates and simplifies patch management and security bulletin management on hp ux systems. Installing hp applications and patches hpux 11i v3 installation and update. Veritas netbackup bare metal restore administrators guide. Remember that if you have any kernel patches, the system will for sure reboot. Electronic software notifications and delivery the hp ux 11i v3 electronic software delivery model has been extended worldwide. Older patch sets usually have these 3 bundles but the recent last 45 years have just the qpk quality pack set.

How to verify current patch information on hpux 11i. Configure persistent image registry in openshift using nfs. Mar 24, 2009 hp ux patches are sd products, but ignite ux can only manage sd bundles. We highly recommend you download the following bundles. The following command sets the bundle name b and the tilte of the. Itrc howdy folks, in keeping my servers patched up to date, i normally use the swainv shell script to generate inventory.

Select the create as container database option to create the database as a multitenant container. Bladelogic selects only one out of the two patch in the bundle but not the entire bundle. Hpux software assistant standard hpux patch bundles. How build a depot with all hpux fibre channel driver. Rerun swlist on this depot to verify that the bundle has been created. To create a nonprivileged account on an hpux monitored device, complete the following steps. A patch aggregate kit is one large patch kit for openvms and tru64 unix, that contains several individual patches that have been repackaged. The server will need to be rebooted afterwards since kernel patches are being installed. Below are the prechecks that need to be completed before proceeding with the installation of grid and oracle softwares. A patch bundle is a set of patches for hpux that have received extra testing as a group and are packaged together, with the individual patches intact. The hp ux 11i september 2005 quality pack patch bundle provided support for etc dld. Your first encounter with patch bundles might be with the standard hp ux patch bundles. Step by step nfs server and client configuration in hpux. Convert the individual patches into a single bundle and put the bundle in the patches depot.

On the ignite server, mount hps core os cd for an os version for which you want to create a depot. So i have downloaded the patches in a bundle from the hp website and unpacked them in a location from which i like to install them. Hpux iscsi host to mdsips8 configuration example cisco. Overview use cases and recommendations bundle patch 1 compatibility matrix 1. I am trying to create a depot from many patches in hpux 11. Hpux 11i v3 update 2 no, seriously features some tweaks to the kernel and elsewhere, providing what hp claims is a 20 per cent performance boost over. Hpux 11i v3 2017 operating environment update release. In the production environment, store copies of the following files. How build a depot with all hpux fibre channel driver bundles.

Hpux 4 openshift 3 rhel atomic hosts 2 uncategorized 1 archives. Create a user or use an existing nonprivileged user. These bundles enable new hardware, fix known defects, and provide. How to verify current patch information on hpux 11i wiki. The hpux oe media provides standard hpux patch bundles for hpux core file sets and applications, plus diagnostic products. This article explains a method to create a software distributor depot with all hpux fibre channel driver bundles for an specific hpux release. In addition to the above patches the enablevxfs bundle needs to be installed before installing the vxfs 5. To update to hp ux 11i v3 and include a specific hp ux 11i v3 oe, you need to specify the oe name in the update ux command. The fix consists of two parts, one from the vxfs patch and the other from the odm patch. Create postinstallation swa report to verify that all recommended patch. Q quality pack qpk a bundle of hp ux defectfix patches for proactive patching. Hp ux 11i version 3 2017 update standard name and dvd labels hp ux 11. In this article, we will be doing prechecks for oracle 11gr2 rac installation on hpux. Swa combines the versatility and power of the hp it resource center itrc patch assessment and security patch check spc utilities, and is the hprecommended utility to use to maintain currency with hppublished security bulletins.

1564 292 866 141 1394 1298 1321 439 79 1560 338 1455 191 235 706 22 1368 1036 33 1293 18 992 861 318 502 42 567 797 805 1445 520 1077 265 351 451 1146 832 958 356 622 89 100 930 560 131 497 117 240